EARLY WARNING
Composite or individual analysis of the key fault gases dissolved in power transformer oil for early warning indication and initial fault classification.The HYDROCAL 1001+ is a permanently-installed composite gas-in-oil sensor for the analysis of six dissolved key fault gases such as Hydrogen (H2), Carbon Monoxide (CO), Methane (CH4), Acethylene (C2H2), Ethylene (C2H4), and Ethane (C2H6). To detect an even wider range of potential transformer faults, the HYDROCAL 1001+ analyses additionally the content of Moisture (H2O) in the transformer oil.
INTENSIVE CARE
Permanently installed online DGA (Dissolved Gas Analysis) devices for the individual analysis of multiple gases and detailed fault classification.The HYDROCAL 1005 is a permanently-installed multi-gas-in-oil analysis system with transformer monitoring functions. It allows for the individual measurement of Moisture in Oil (H2O) and the key gases Hydrogen (H2), Carbon Monoxide (CO), Acetylene (C2H2) and Ethylene (C2H4) dissolved in transformer oil.
PORTABLE DGA
Portable device for the analysis of dissolved and free gases from the isolation fluid of oil-filled power transformers and other electrical equipment.The HYDROCAL 1011 genX P is a portable device for the analysis of dissolved and free gases from the isolation fluid of oil-filled power transformers and other electrical equipment. It individually measures moisture in oil (H2O) and the key gases hydrogen (H2), carbon monoxide (CO), carbon dioxide (CO2), methane (CH4), acetylene (C2H2), ethylene (C2H4), ethane (C2H6), oxygen (O2), nitrogen (N2) and propane (C3H8) dissolved in transformer oil.
HYDROCAL GENX
The new HYDROCAL genX product family is the first truly maintenance-free multigas online DGA (Dissolved Gas Analysis) solution combining proven near infrared (NIR) measuring technology with vacuum protected membrane extraction.The new HYDROCAL 1004 genX is the first truly maintenance-free multi-gas online DGA solution combining proven near infrared (NIR) measuring technology with vacuum protected membrane extraction.
BUSHING MONITORS
Bushings or the line output represent the second largest group of transformer failures (about 25%) after windings (43%) and before tap changers (23%). Therefore, bushing monitoring can help reduce these errors, while UHF partial discharge analysis of the active part of a power transformer is an ideal combination with online DGA from the HYDROCAL product family.
SOFTWARE